Forensic Equipment from AirClean Systems

PCR Workstations

PCR Workstations

Get Results—Not Background!

AirClean® Systems PCR workstations allow you to maintain a clean work area during PCR preparation. The AC600LFUV has a built-in 254 nm ultraviolet light that allows the operator to irradiate tubes, flasks and pipettes between amplifications. The 254 nm ultraviolet light will effectively destroy potentially contaminating DNA and RNA within minutes.

The workstations feature a unique interlocking sash with a safety overlap to prevent gaps. The sash also has a safety switch that automatically turns off the ultraviolet light and activates the blower and fluorescent light when the sash is raised. This revolutionary uni-body design provides unmatched user protection from harmful ultraviolet rays during the sterilization process. HEPA filtered units have a built-in monitoring system to alert the user when to change the HEPA filter.

Typical Workstation Airflow:

  1. Room air enters at "A"
  2. Air forced through HEPA filter creating laminar flow
  3. Clean laminar flow air enters at "B" and exits at "C"
  4. UV light sterilizes pipette tips, tubes and flasks

Features:

  • Class 100 vertical laminar flow
  • 254 nm ultraviolet light with 0-15 minute automatic timer
  • Bi-fold sash with safety interlock
  • 360-degree visibility
  • Integral polypropylene base for easy cleaning
  • Low-profile design using all thermoplastic construction
  • Built-in fluorescent light
  • HEPA filter monitor automatically indicates when filter change is required
  • Available in 110V or 220V models

Options:

  • ACA1037 Two Speed Blower—increases filter life and enables ultra-quiet background operation.
  • ACA1038 Variable Blower Controller—for 0-100% control of blower speed.
  • ACA1011 Custom Sturdy Cart for AC632—allows unit to be portable.
  • ACA1039 Custom Sturdy Cart for AC648—allows unit to be portable.
  • ACA1040 Removable Shelf—allows pipette tips and tubes to be placed closer to UV light for irradiation. Note: Two shelves required for AC648.
  • ACA1041 Decontamination Spray—Formulated to provided high-level disinfection without damaging workstation components.
CAT. # DESCRIPTION
AC632DB Dead Air Box, 32" wide
AC632LF Class 100 laminar flow, 32" wide
AC632LFUV Combination class 100 Laminar flow and UV light sterilization, 32" wide
AC648DB Dead Air Box, 48" wide
AC648LF Class 100 laminar flow, 48" wide
AC648LFUV Combination Class 100 Laminar flow and UV light sterilization, 48" wide

AC600 Series - Three Models:

DB – Circulation free environment with UV light sterilization. This unit has a UV light with 0-15 minute timer for sterilization between amplifications. A safety interlock switch prevents exposure to UV light when sash is raised.
LF – Provides Class 100 vertical laminar flow air through a 99.997% HEPA filter.
LFUV – Combines a Class 100 clean air environment with UV light sterilization for optimal protection from sample contamination. Raising the bi-fold sash turns off the UV light and enables the blower.

AirClean® AC600 Series Specifications
AC632DB AC632LF AC632LF AC648DB AC648LF AC648LFUV
Width 32" 32" 32" 48" 48" 48"
Depth 24" 24" 24" 26" 26" 26"
Height 30" 30" 30" 32" 32" 32"
Ship Weight 100 lbs. 125 lbs. 150 lbs. 125 lbs. 150 lbs. 200 lbs.
Noise Level N/A <49DBA <49DBA N/A <53DBA <53DBA
Voltage 110V or 220V 110V or 220V 110V or 220V 110V or 220V 110V or 220V 110V or 220V
Power 20 Watts 200 Watts 200 Watts 40 Watts 400 Watts 400 Watts
UV Light 15W 254 nm N/A 15W 254 nm 2-15W 254 nm N/A 2-15W 254 nm
Blower N/A Sparkless/Brushless Sparkless/Brushless N/A Sparkless/Brushless Sparkless/Brushless
UV Light Timer 0-15 minutes N/A 0-15 minutes 0-15 minutes N/A 0-15 minutes
Safety Interlock Yes N/A Yes Yes N/A Yes
Air Velocity N/A 100LFM/60LFM 100LFM/60LFM N/A 100LFM/60LFM 100LFM/60LFM

Back to Top

Upcoming Tradeshows:

IAFS
July 21-26
New Orleans, LA

IAI
August 17-23
Louisville, KY

ASCLD
September 16-18
Salt Lake City, UT

FDIAI
October 26-30
Panama City, FL